__

Temporary Power Restoration Products

At Bridgeport Magnetics Group, we help utility companies and linemen achieve fast temporary power restoration. Our PowerBack and Trident toroidal autotransformers deliver reliable balanced 120/240V service in minutes, with superior portability, efficiency, and rugged reliability for emergency outage response.

01 · Overview

Temporary Power Restoration at the Meter in Minutes

Bridgeport Magnetics’ temporary power restoration autotransformers (PowerBack and Trident) regenerate a missing hot leg or neutral directly at the meter socket – restoring full balanced 120/240V or 120/208V service within minutes while permanent repairs are scheduled.

Designed by linemen, for linemen in collaboration with utilities, every PowerBack and Trident unit is manufactured in Shelton, Connecticut with a fast 1–2 week lead time. Built with high-efficiency toroidal cores, they include voltage and amperage monitoring plus redundant 2× trip overcurrent protection for safe, confident deployment in the field.

Trusted By

Our Customers

02 · Models

PowerBack & Trident Models

Compare ratings, enclosures, and features across the lineup.

Trident Powerback-Lite 15KVA Powerback-Lite 20KVA Powerback 15kVA Powerback 20kVA Powerback 30kVA Powerback 50kVA
Temporary Power Restoration Trident 45lb service saver Powerback Lite Powerback Lite utility industry, Temporary Power Restoration utility industry, Temporary Power Restoration utility industry, Temporary Power Restoration Bridgeport Magnetics PowerBack 50 kVA multi-home temporary power restoration unit, a wheeled NEMA 4 toroidal autotransformer that restores a missing 120V hot leg or neutral on 400A services.
High Efficiency Toroidal Auto Transformer 20kVA (2x10kVA) 15kVA 20kVA 15kVA 20kVA 30kVA 50kVA
Recommended Service 100A (oneAuto) 200A (twoAuto) 150A 200A 150A 200A 320A 400A
Circuit Breaker 2x50A 125A 160A 125A 160A 250A 400A
(Dual Protections) Shunt Trip Temp. degC NA 105 105 105 105 105 105
Corded Meter Adapter Included 200A 200A 200A 200A 200A 320A No meter adapter - Cam-Lok kit, 10 ft 1/0 & 3/0 leads, 9-pc Flood-Seal/tinned whips.
Input/Output Voltmeters Yes Yes Yes Yes Yes Yes NA
Integrated GFI with Defeat Switch Optional Optional Optional Optional Optional Optional NA
GPS Tracking Optional Optional Optional Optional Optional Optional Optional
Enclosure Type Resin Case Resin Case Resin Case NEMA 4 Stainless NEMA 4 Stainless NEMA 4 Stainless NEMA 4 Stainless
Grounding No Grounding Required No Grounding Required No Grounding Required YES YES YES YES
Dimensions (inches) NA 29 x 22 x 13 29 x 22 x 13 29 x 22 x 13 29 x 22 x 13 29 x 22 x 13 46 x 35 x 20
Wheels (Diameter x Width) NA 10.5" x 3" 10.5" x 3" 10.5" x 3" 10.5" x 3" 10.5" x 3" 12" x 4.5"
Weight (lbs.) 45 / Auto 91 110 120 140 220 290

A toroidal core makes Power-Back dramatically lighter than conventional E-I lamination units, so a single lineman can position it at the meter pan without a hoist or a second set of hands.

Two independent trip paths: transformer
winding temperature and overcurrent. If either limit is reached,
PowerBack disconnects itself. Leave it on-site with confidence.

Puncture proof / airless tires for rough deployments –
driveways, gravel, mud, and storm debris.

Connect at the meter in one turn. The Power-Back meter adapter installs fast and includes a neutral – so you restore service in minutes instead of running temporary above-ground conductors.

Every Power-Back is Manufactured in Shelton, Connecticut, with a 1–2 week lead time. No import delays.

04 · How It Works

When a Single Leg Fails, Don't Leave Customers in the Dark

An open hot leg or neutral – caused by a storm, damaged underground cable, or equipment fault – can drop a customer’s service even when the upstream transformer is intact. Locating and repairing the fault often takes days.

Temporary power restoration autotransformers (also known as add-a-phase or service-saver devices) solve this by connecting between the meter socket and the meter to quickly regenerate the missing leg and restore full balanced 120/240V or 120/208V service.

PowerBack and Trident systems restore load current on an open hot leg up to their rated capacity and full service on an open neutral up to their neutral current rating – giving your crews the flexibility to schedule permanent repairs on their own timeline instead of working under emergency pressure.

05 · TRIDENT

When wheeling a cart isnt an option - rough terrain, flooded ground, easements, backyards - the Trident goes where a wheeled unit can't.

The first handheld modular toroidal restoration unit at <50lb weight – purpose-built with line crews and Unions with strict weight restrictions

~45 lb per transformer plus a 9 lb control unit. Built for easements, backyards, gravel, and flooded ground – restore service where wheeling is impossible.

A new weatherproof enclosure protects the unit through restoration in any conditions.

Connect at the meter in one turn. The Power-Back meter adapter installs fast and includes a neutral – so you restore service in minutes instead of running temporary above-ground conductors.

Every Trident is Manufactured in Shelton, Connecticut, with a 1–2 week lead time. No import delays.

Designed by Linemen, for Linemen

Back online in days, not weeks.

PowerBack and Trident temporary power restoration autotransformers – developed hand-in-hand with utility line crews, engineered and built in Shelton, Connecticut.

06 · FAQ

Frequently Asked Questions

What is a temporary power restoration autotransformer?

A temporary power restoration autotransformer is a secondary device – also called a service saver, add-a-phase, add-a-leg, phase restoration unit, auto cart, or Servisavor-style unit – that regenerates a missing hot leg or missing neutral on single-phase 120/240V or 120/208V service. Two of the three conductors still have to be good. PowerBack (wheeled), PowerBack Lite, and Trident (carry-in) restore at the meter. The 50 kVA PowerBack restores a multi-meter cabinet or pedestal on the incoming secondary. Customers stay online while the underground repair is scheduled.

Most PowerBack, PowerBack Lite, and Trident units connect at the meter. Isolate the faulted conductor, remove the meter, land the single-turn adapter (ring-type or ringless; CL320 on the 30 kVA), set the meter back on, and energize. Neutral is in the adapter. No temporary overhead.

The 50 kVA PowerBack does not use a meter adapter. It lands on the cabinet or pedestal secondary with a Cam-Lok kit: 10 ft 1/0 and 3/0 leads, then a 5 ft Flood-Seal or tinned whip.

Same electrical job: restore a missing hot or a missing neutral. PowerBack is the wheeled service saver for sites a cart can reach (Lite at 91–110 lbs, stainless 15–30 kVA, 50 kVA for multi-home cabinets). Trident is the 45 lb one-person carry-in service saver for stairs, alleys, gates, and finished yards. Designed by linemen, for linemen.

Yes. PowerBack and Trident restore a missing hot or a missing neutral. Two conductors must still be good. They cannot restore a hot and the neutral at the same time on the same service. Size the unit to the ticket: 15 kVA / 150A, 20 kVA / 200A, 30 kVA / 320A, 50 kVA / 400A multi-home, or Trident 100A / 200A by module count.

Yes. Protection is built for a unit that may sit for days, not only for the minute you close the breaker.

PowerBack and PowerBack Lite (wheeled) use dual-trip protection – two independent paths to the same breaker:

  • Path 1 – overcurrent. A model-rated breaker opens on high current (short or severe overload): 125A on 15 kVA, 160A on 20 kVA, 250A on 30 kVA, 400A on 50 kVA.
  • Path 2 – winding temperature. A 105°C sensor at the transformer – not on the cabinet wall – shunt-trips that same breaker if the core and copper overheat while current is still under the breaker rating. A breaker alone does not see slow heat from load, blocked airflow, ambient temperature, or solar export.

If either path fires, PowerBack disconnects itself. 15–30 kVA models also have a digital input/output voltmeter so the crew reads 120V hot-to-neutral and 240V hot-to-hot before they leave. Optional GFI (defeat switch) and optional GPS.

Trident uses per-module protection instead of the 105°C shunt trip. Each 10 kVA autotransformer has its own 50A breaker. If only one module is installed and the house needs more than that module can carry, Trident shuts off – protecting the transformer and the home. Built-in voltage and current monitoring is the second trip path. Confirm the reading at the control unit before you leave.

Yes – every PowerBack and Trident temporary power restoration autotransformer is designed, wound, and assembled in Shelton, Connecticut. This domestic manufacturing provides reliable 1–2 week lead times with no import delays, helping utilities maintain strong fleet readiness.

Temporary power restoration autotransformers are primarily used by electric utilities, line crews, and contractors during storm recovery, underground cable faults, planned maintenance, and emergency outages. They are especially valuable for residential, multi-family, and light commercial services where fast restoration improves SAIDI/SAIFI metrics and customer satisfaction.

Temporary power restoration can be installed days to a few weeks – until the permanent repair is scheduled and completed. That is the job. Confirm voltage before you leave. Dual-trip on PowerBack, and per-module overcurrent on Trident, watch the unit while it sits. Remove it when the cable or connector is fixed.

Yes, on 120/240V or 120/208V single-phase service, if two conductors are still good and the install follows your utility’s procedure.

Best practice is to isolate or disconnect the solar equipment before you leave the unit on-site. A service saver does not block reverse power. Once voltage is restored at the meter, the inverter may stay online or reconnect. Export then adds current through the unit and extra heat in the windings.

If the array stays connected: treat export as added load, size the unit up if needed, and confirm voltage and current before you leave. Do not assume the inverter is off just because one utility conductor is open. If the unit trips, do not reset and walk away – check whether the array is exporting. PowerBack dual-trip (breaker + 105°C winding shunt trip) is the extra layer on a solar house that may sit for days.

Shopping Cart
Products
Toroidal transformers & magnetics — made in Shelton, CT since 1982
Made in USA  ·  Intertek (ETL) Certified  ·  UL Recognized

Product Inquiry Form